STUDS (GENERAL INFORMATION)

CD AND ARC STUDWELD TESTING (PHYSICAL)
If, after visual inspection the weld quality is still questionable, or specifications require, the welded stud can be submitted to additional testing. The following are suggested physical tests.
Picture
Bend Test: (See illustrations) By striking the stud with a hammer, or by sliding a length of pipe or tube over the stud, the stud can be bent a minimum of 30° away from its axis, or until failure occurs. Satisfactorily welded studs should exhibit a complete 90° bend without failure.

Torque Test: The stud may be torqued with conventional torque testing equipment by applying torque until a predetermined torque or proof load is reached or until failure occurs.

Bend Test with Hammer.
Picture
Tensile Test: The stud may be tested with conventional tensile testing equipment until a predetermined load is reached or until failure occurs.

Other: The stud and weld can be submitted to other conventional forms of destructive or nondestructive testing as specifications may required.

Bend Test with Pipe.