All information conatained herein is subject to change without notice.
For more information-consult your nearby Continental Field sales representative.

STUDS (GENERAL INFORMATION)

CD STUD LOAD STRENGTHS
STUD MATERIAL
STUD SIZE
SUGGESTED MAX. FASTENING TORQUE (INCH LBS.)*
ULTIMATE TENSILE LOAD (LBS.)

Low-Carbon,
Copper-Flashed
Steel

6-32
8-32
6.0
12.0
500
765
10-24
1/4-20
14.0
43.0
960
1750
5/16-18
3/8-16
72.0
106.0
2900
4300
Stainless Steel:
304
6-32
8-32
10.0
20.0
790
1260
10-24
1/4-20
23.0
75.0
1530
2880
5/16-18
3/8-16
126.0
186.0
3750
4850
Aluminum
Alloy:
5356

6-32
8-32
3.5
7.5
375
585
10-24
1/4-20
10.0
32.5
735
1360
5/16-18
3/8-16
70.0
81.0
2300
3250
Aluminum
Alloy:
6061
6-32
8-32
6.5
13.0
350
560
10-24
1/4-20
19.0
40.0
670
1240
5/16-18
3/8-16
70.5
100.0
2025
2985
Brass:
70-30(260)
65-35(268)

6-32
8-32
8.0
16.0
600
860
10-24
1/4-20
18.5
61.0
1040
1950
5/16-18
3/8-16
102.0
150.0
3280
4800
*These values should develop fastener tension to slightly less than yield point.